Oktober-TEST, Part 3. All month, we’re opening the lab doors on specialty methods SPL’s technical services team runs every day. Last week we dove into how WET Testing works. This week we’re shining the spotlight on LNG feed gas analysis.
Key Points
- Before liquefaction, LNG feed gas must have its carbon dioxide and its hydrocarbons heavier than propane removed, because those components can freeze into solids.
- A GPA 2286 extended gas analysis alone can’t analyze the portion of the heavy end that stays in the liquid phase at analysis conditions (about 140°F at sample pressure).
- SPL developed a modified solvent extraction procedure, to recover trace liquids that weigh under 0.100 grams from sample cylinders weighing over 1 kilogram, over 4x above the upper limits of most high-precision analytical balances.
- The extract is analyzed by GC using GPA 2186M. The results go through peak-by-peak review in Dragon II DHA software and are delivered through SureChem.
Natural gas streams destined for use in liquefied natural gas (LNG) storage and export must meet specific composition requirements before liquefaction can occur. Carbon dioxide and hydrocarbons heavier than propane must be removed or reduced to acceptable low levels to prevent solid formation under cryogenic conditions, which can interfere with LNG processing.
Accurate feed gas composition analysis supports LNG facility design, processing, and incoming gas volume accounting. However, conventional extended gas analysis does not account for the majority of residual heavy hydrocarbons that remain in the liquid phase during testing.
To address this analytical challenge, SPL developed a supplemental solvent extraction approach that complements traditional gas composition analysis and enables further characterization of residual heavy hydrocarbons through analysis method we will explain in this article..
Understanding the Limitations of Extended Natural Gas Analysis
The most common extended gas analysis method used in the industry, GPA 2286, is designed to characterize natural gas composition, including trace levels of select heavy hydrocarbons through decanes or C10. However, under certain analytical conditions, heavy hydrocarbon components may remain in the liquid phase, causing an inadequate representation of the gas-phase results in these critical situations.
At approximately 140 °F, one of the most common temperatures used to heat the gas cylinders, and sample pipeline pressure, a portion of heavy hydrocarbons may remain as a liquid within the sample cylinder and not vaporize into the gas phase for analysis. These quantities can be extremely small: an 1100-gram cylinder containing 8 grams of natural gas may contain less than 0.100 grams of residual heavy liquid.
To better characterize this material, SPL developed a supplemental extraction approach using a solvent to recover hydrocarbons for further analysis. The recovered material can then be evaluated using gas chromatography (GC) analysis, providing additional insight into the heavy hydrocarbon composition of LNG feed gas.
Using Dichloromethane for Heavy Hydrocarbon Extraction
Dichloromethane is one of the most commonly used solvents to extract hydrocarbons from sample materials. This is due to its ability to highly dissolve hydrocarbon molecules and relatively low temperature of evaporation.
One established extraction technique using dichloromethane is the Soxhlet extraction, a widely recognized laboratory process for separating extractable compounds from solid or powder materials.
Using the Soxhlet extraction as inspiration, SPL has developed modified approaches for different sample applications, including hydrocarbon analysis of sludge samples and residual hydrocarbon characterization in natural gas samples.
For LNG feed gas applications, SPL’s supplemental solvent extraction approach provides a means of recovering trace liquid hydrocarbons that may remain after conventional gas composition testing.
The extracted material can then be analyzed using GC analysis to provide additional information about the heavier hydrocarbon components of the sample. Thus, this testing helps address the analytical limitations that arise from conventional gas-phase analysis alone.
Complementing Extended Gas Analysis with DHA or HTSD Testing
Following extraction, the recovered heavy hydrocarbon material is analyzed using gas chromatography. The resulting chromatographic data provides information that can be evaluated through detailed hydrocarbon analysis (DHA) or high-temperature simulated distillation (HTSD).
DHA, also known as a PIANO analysis, is a high-resolution GC method which focuses on component identification and classifying hydrocarbons. The constraint of this analysis is that the heaviest hydrocarbon able to be analyzed is C30. Originally called PIONA to differentiate from a classical piano. However, the industry now uses PIONA and PIANO interchangeably. Dragon II DHA reports sort the classifications as PIONA, even though language lingo for communication often references the report as a PIANO.
PIANO is an acronym derived from the classifications of components from the analysis:
- Paraffins: Saturated hydrocarbons with straight-chain structures. In other areas of chemical study, these are known as straight-chain alkanes.
- Isoparaffins: Saturated hydrocarbons with branched chain structures, or branched alkanes.
- Aromatics: Hydrocarbons containing aromatic ring structures.
- Naphthenes: Saturated cyclic hydrocarbons, also known as cyclic alkanes.
- Olefins: Unsaturated hydrocarbons containing carbon-carbon double bonds, also known as alkenes.
High-Temperature Simulated Distillation (HTSD) is a low-resolution GC analysis that uses high-temperature gas chromatography to determine boiling point distribution and cut point intervals. This covers a larger hydrocarbon range than DHA, as far as C100 rather than C30, allowing for identification of heavier hydrocarbon materials when it is known that lubricants and heavy crude oils are potentially present in the gas samples. However, this method loses the ability to differentiate molecule types that DHA or PIANO can identify.
This additional can provide a more detailed understanding of the residual hydrocarbon material present in natural gas samples. For LNG facilities, the ability to supplement conventional gas composition data with information about residual heavy hydrocarbons supports a more complete evaluation of incoming feed gas composition. For most LNG needs, a PIANO analysis will show sufficiently high molecular weight components. HTSD is a more fitting analysis if there is known or suspected lubricant oil contamination.
Understanding Heavy Hydrocarbons in LNG Feed Gas
Heavy hydrocarbon characterization is particularly relevant to LNG processing because feed gas composition influences the treatment required before liquefaction.

Natural gas entering an LNG facility may contain components that must be reduced or removed to meet processing and product specifications. Certain heavier hydrocarbons, particularly some aromatic compounds, can form solids under cryogenic conditions.
These components can present challenges within the liquefaction process if they are not adequately addressed during feed gas treatment.
Routine gas composition analysis helps LNG operators and engineers understand the incoming natural gas stream and supports the design and operation of treatment processes.
However, when a portion of the heavy hydrocarbon fraction remains in the liquid phase during conventional analysis, supplemental characterization can provide additional information.
This information is relevant to several aspects of LNG facility operations:
- Feed gas characterization: Understanding the composition of natural gas entering the facility, including residual heavy hydrocarbon components.
- Process design: Providing additional composition information for evaluating feed gas treatment requirements.
- Operational considerations: Supporting the evaluation of hydrocarbon components that may affect liquefaction processes.
- Incoming gas accounting: Supplementing the composition data used to evaluate incoming feed gas volumes.
PIANO Analysis and Detailed Hydrocarbon Reporting

Following gas chromatographic analysis, SPL evaluates the resulting analytical data to characterize the recovered hydrocarbon material. SPL uses Dragon DHA software to support hydrocarbon identification and analysis. The resulting information is compiled into a laboratory report that includes relevant sample documentation and analytical results. Final reports are made available through SPL’s SureChem system.
Solvent extraction, gas chromatography, and detailed hydrocarbon analysis provide an additional means of characterizing residual heavy hydrocarbons that may not be adequately represented in conventional gas-phase testing. This data, combined with the classic extended gas chromatography provides a comprehensive picture of the sample as a whole.
Supporting LNG Feed Gas Characterization Through Complementary Testing
For LNG operators, gas processors, and consulting engineers, understanding feed gas composition is essential to making informed decisions about facility design and processing requirements.
SPL’s Energy Laboratories provide specialized hydrocarbon characterization capabilities to support these decisions with additional analytical insight.
Contact SPL’s Energy Laboratories team to discuss your LNG feed gas testing needs.
Frequently Asked Questions
Why do heavy hydrocarbons need to be removed from LNG feed gas?
Certain heavy hydrocarbons can form solids under the cryogenic conditions used during LNG production. LNG facilities must reduce or remove these components to meet process and product specifications and minimize potential operational problems during liquefaction.
Can GPA 2286 Extended Gas Analysis measure all the heavy hydrocarbons in LNG feed gas?
GPA 2286 is designed to characterize extended natural gas composition, including heavier hydrocarbons. However, some samples may contain residual liquid hydrocarbons that are not adequately represented in the gas phase analysis. Supplemental testing can provide additional information about these materials.
What is the purpose of solvent extraction in LNG feed gas analysis?
Solvent extraction provides a means of recovering trace residual hydrocarbons for additional laboratory characterization. SPL uses dichloromethane as part of its supplemental analytical approach to characterize residual heavy hydrocarbon material in natural gas samples.
What is PIANO analysis?
PIANO analysis characterizes hydrocarbons according to five classifications: paraffins, isoparaffins, aromatics, naphthenes, and olefins. When used alongside gas chromatography and detailed hydrocarbon analysis, it provides additional information about hydrocarbon composition.
How does supplemental heavy hydrocarbon testing benefit LNG facilities?
Supplemental testing provides additional information about residual heavy hydrocarbons that may not be adequately represented by conventional gas-phase analysis. This information can support feed gas characterization, process design considerations, and evaluation of incoming natural gas composition.
Get a More Complete Picture of Your LNG Feed Gas Composition
Understanding the heavy hydrocarbon content of incoming natural gas is an important part of LNG feed gas characterization.
SPL’s Energy Laboratories offer specialized analytical capabilities that complement conventional gas composition testing and provide additional insight into residual heavy hydrocarbons.
Contact SPL’s Energy Laboratories team to discuss solvent extraction and PIANO analysis for your natural gas testing needs.
Account for Every Component in Your Feed Gas