EDB & DBCP

Matrix: DW NP Method: EPA 504.1 Sample Requirements Bottle Glass Vial 40 mL (ZHE)5 Min. Volume (mL)3: 40 Preservation: Cool to < 6°C Holding Time: 14 Days Notes 01. AbbreviationsDW = Drinking WaterNP = Non Potable (includes wastewater, surface water, etc.)HW = Hazardous Waste 02. Sample lists typical bottle provided by Ana-Lab. 03. […]

Read More

DOC

Matrix: DW/NP NP Method: SM 5310 C Sample Requirements Bottle Glass Qt, Amber Min. Volume (mL)3: 1000 Preservation: Cool to < 6°C Holding Time: 48 Hours Notes 01. AbbreviationsDW = Drinking WaterNP = Non Potable (includes wastewater, surface water, etc.)HW = Hazardous Waste 02. Sample lists typical bottle provided by Ana-Lab. 03. The […]

Read More

DIQUAT/PARAQUAT

Matrix: DW NP Method: EPA 549.1 Sample Requirements Bottle 500 mL HD Amber PVC Min. Volume (mL)3: 500 Preservation: 100 mg Na2S2O3, Cool to <6°C Holding Time: 7 Days Notes 01. AbbreviationsDW = Drinking WaterNP = Non Potable (includes wastewater, surface water, etc.)HW = Hazardous Waste 02. Sample lists typical bottle provided by […]

Read More

DISSOLVED OXYGEN (ON-SITE)

Matrix: NP NP Method: SM 4500-O G Sample Requirements Bottle Glass Min. Volume (mL)3: 100 Preservation: None Required Holding Time: Analyze Immediately (within 15 minutes) Matrix: NP/HW NP Method: SM 4500-O G / EPA 360.1 Sample Requirements Bottle Glass Min. Volume (mL)3: 100 Preservation: None Required Holding Time: Analyze Immediately (within 15 minutes) Notes 01. AbbreviationsDW […]

Read More

DIOXINS/FURANS

Matrix: DW NP Method: EPA 1613 Sample Requirements Bottle Amber Glass Qt4 with Teflon lined lid Min. Volume (mL)3: 1000 Preservation: Cool to < 6°C Holding Time: Notes 01. AbbreviationsDW = Drinking WaterNP = Non Potable (includes wastewater, surface water, etc.)HW = Hazardous Waste 02. Sample lists typical bottle provided by Ana-Lab. 03. […]

Read More

DICOFOL / METHOXYCHLOR / MIREX

Matrix: NPNP Method: EPA 617 Sample Requirements Bottle Amber Glass Qt4 with Teflon lined lid Min. Volume (mL)3: 1000 Preservation: Cool to < 6°C Holding Time: 7 days to extract, 40 days to analyze Matrix: NP/HWNP Method: EPA 8081A Sample Requirements Bottle Amber Glass Qt4 with Teflon lined lid Min. Volume (mL)3: 1000 Preservation: […]

Read More

CARBARYL / DIURON

Matrix: NPNP Method: EPA 632 Sample Requirements Bottle Amber Glass Qt4 with Teflon lined lid Min. Volume (mL)3: 1000 Preservation: Cool to < 6°C Holding Time: 7 days to extract, 40 days to analyze Matrix: HW/SNP Method: EPA 8321B Sample Requirements Bottle Glass 4 oz with Teflon lined lid Min. Volume (mL)3: Preservation: Cool […]

Read More

REACTIVITY CYANIDE (TOTAL)

Matrix: HW/SNP Method: EPA 9014 MOD Sample Requirements Bottle Glass 8 oz with Teflon lined lid Min. Volume (mL)3: Preservation: Cool to < 6°C Holding Time: 14 Days Notes 01. AbbreviationsDW = Drinking WaterNP = Non Potable (includes wastewater, surface water, etc.)HW = Hazardous Waste 02. Sample lists typical bottle provided by […]

Read More

CYANIDE, AMENABLE

Matrix: DW/NP NP Method: SM 4500-CN¯ G Sample Requirements Bottle Polyethylene 250 mL/ amber Min. Volume (mL)3: 500 Preservation: NaOH to pH >12, Cool to < 6°C Holding Time: 14 Days Matrix: NP/HW NP Method: EPA 9014 Sample Requirements Bottle Polyethylene 250 mL/ amber Min. Volume (mL)3: 500 Preservation: NaOH to pH >12, Cool to < […]

Read More