Matrix: NP/HWNP Method: EPA 8015B *MOD Sample Requirements Bottle 125mL Glass vial (ZHE)5 Min. Volume (mL)3: 125 Preservation: HCl to pH <2, Cool to < 6°C Holding Time: 7 days to extract, 40 days to analyze Notes 01. AbbreviationsDW = Drinking WaterNP = Non Potable (includes wastewater, surface water, etc.)HW = Hazardous […]
Read MoreEnvironmental Test List
environmental lab tests by name
TPH GRO/GAS EXPANSION
Matrix: NP/HWNP Method: EPA 8015B Mod Sample Requirements Bottle 125mL Glass vial (ZHE)5 Min. Volume (mL)3: 125 Preservation: HCl to pH <2, Cool to < 6°C Holding Time: 7 days to extract, 40 days to analyze Matrix: HW/SNP Method: EPA 8015B Mod Sample Requirements Bottle Glass 4 oz with Teflon lined lid8 Min. Volume […]
Read MoreTCLP
Matrix: NP/HWNP Method: EPA 1311 Sample Requirements Bottle Glass Qt Min. Volume: 7 qts Preservation: Cool to < 6°C Holding Time: 14 Days Notes 01. AbbreviationsDW = Drinking WaterNP = Non Potable (includes wastewater, surface water, etc.)HW = Hazardous Waste 02. Sample lists typical bottle provided by Ana-Lab. 03. The minimum volume […]
Read MoreTCLP (SOLID)
Matrix: HW/SNP Method: EPA 1311 Sample Requirements Bottle Glass Qt Min. Volume (mL)3: 1 qt7 Preservation: Cool to < 6°C Holding Time: 14 Days Notes 01. AbbreviationsDW = Drinking WaterNP = Non Potable (includes wastewater, surface water, etc.)HW = Hazardous Waste 02. Sample lists typical bottle provided by Ana-Lab. 03. The minimum […]
Read MoreSILICA
Matrix: NPNP Method: EPA 200.7 4.4 – Calc Sample Requirements Bottle Polyethylene 500 mL Min. Volume (mL)3: 100 Preservation: HNO3 to pH <2 , Cool to < 6°C Holding Time: 180 Days Matrix: NP/HWNP Method: EPA 6010C – Calc Sample Requirements Bottle Polyethylene 500 mL Min. Volume (mL)3: 100 Preservation: HNO3 to pH <2 […]
Read MoreSPECIFIC CONDUCTANCE
Matrix: DW/NP NP Method: SM 2510 B Sample Requirements Bottle Polythylene Qt Min. Volume (mL)3: 200 Preservation: Cool to < 6°C Holding Time: 28 Days Matrix: NP/HW NP Method: EPA 9050A Sample Requirements Bottle Polythylene Qt Min. Volume (mL)3: 200 Preservation: Cool to < 6°C Holding Time: 28 Days Matrix: HW/S NP Method: EPA 9050A Sample Requirements Bottle Glass […]
Read MoreSULFATE
Matrix: NPNP Method: EPA 300.0 2.1 Sample Requirements Bottle Polythylene Qt Min. Volume (mL)3: 25 Preservation: Cool to < 6°C Holding Time: 28 Days Matrix: NP/HWNP Method: EPA 9056 Sample Requirements Bottle Polythylene Qt Min. Volume (mL)3: 25 Preservation: Cool to < 6°C Holding Time: 28 Days Notes 01. AbbreviationsDW = Drinking WaterNP = […]
Read MoreSULFIDE
Matrix: NPNP Method: SM 4500-S2¯ D Sample Requirements Bottle Polyethylene 250 mL Min. Volume (mL)3: 500 Preservation: NaOH to pH >9 and Zinc Acetate, Cool to < 6°C Holding Time: 7 Days Matrix: NP/HWNP Method: EPA 376.2 Sample Requirements Bottle Polyethylene 250 mL Min. Volume (mL)3: 500 Preservation: NaOH to pH >9 and Zinc […]
Read MoreSUVA/U254
Matrix: DW/NP NP Method: SM 5910 B Sample Requirements Bottle Glass Qt, Amber Min. Volume (mL)3: 1000 Preservation: Cool to < 6°C Holding Time: 48 Hours Notes 01. AbbreviationsDW = Drinking WaterNP = Non Potable (includes wastewater, surface water, etc.)HW = Hazardous Waste 02. Sample lists typical bottle provided by Ana-Lab. 03. The […]
Read MoreSULFITE (ON-SITE)
Matrix: NP/HWNP Method: SM 4500-SO32¯ B / EPA 377.1 Sample Requirements Bottle Polyethylene or Glass Min. Volume (mL)3: 100 Preservation: None Required Holding Time: Analyze Immediately (within 15 minutes) Notes 01. AbbreviationsDW = Drinking WaterNP = Non Potable (includes wastewater, surface water, etc.)HW = Hazardous Waste 02. Sample lists typical bottle provided […]
Read More