SPL measures your crude’s wax appearance and disappearance temperatures, screens paraffin inhibitors across 15 parallel stations, and confirms the winners on a dynamic wax loop that reproduces your line’s thermal gradient and shear.
Paraffin wax starts to come out of solution once crude oil cools below its Wax Appearance Temperature (WAT). If the fluid properties allow it, those crystals migrate to the pipe wall and build a deposit that narrows the flow path and raises frictional pressure drop. Left unmanaged, wax cuts throughput and forces costly downtime in wells, flowlines and export pipelines.

Wax risk is not a single number. Precipitation follows thermodynamics, but deposition depends on mass transfer, so two crudes with the same WAT can behave very differently in the same line. SPL’s paraffin specialists build every wax assessment on three pillars:
We then layer in your system variables: fluid diffusion, flow rate (wall shear stress) and pipe inner diameter. The result is measured data that lets you push the operating envelope with confidence and set real KPIs for paraffin risk.
Pinpoints the temperature where wax crystals first form (WAT) and fully melt (WDT), the boundaries for every test that follows.
Maps viscosity as a function of temperature so you can see how flow behavior changes as the line cools.
Defines the temperature limit of fluid mobility for shutdown, storage and cold-weather planning.
High-temperature gas chromatography (HTGC/HTSD) profiles the heavy paraffin fraction that drives deposition.
Splits the crude into saturates, aromatics, resins and asphaltenes to assess overall fluid stability.
Ranks paraffin inhibitors, pour point depressants and dispersants side by side on 15 independent stations.
Confirms deposition rates, shear stability and inhibitor performance under flowing, field-representative conditions.
Measures gelled-oil yield stress after controlled cooling so your pumps can restart the line after a shutdown.
SPL’s custom rotating-cage autoclaves use electrically isolated coupon fixtures and controlled rotation speeds to model turbulent flow. We tailor each run to your field operating envelope.
| Parameter | Range or Detail |
|---|---|
| Temperature, low-pressure loop | 20°F to 150°F / -6.7°C to 65.6°C |
| Pressure, high-pressure sister loop | Up to 4,000 psi / 276 bar for deepwater, reservoir-condition and live-fluid work |
| Test section thermal gradient | From above WDT to well below WAT |
| Loop metallurgy | 316 stainless steel, pipe-in-pipe |
| Test substrates | Interchangeable pipe materials, internal coatings and liners |
| Flow and density | Coriolis mass flow meter, continuous logging |
| Pressure drop | Differential pressure transducers along the line |
| Temperature profiling | Distributed thermocouple matrix along the full loop |
| Cold finger screening | 15 independent stations on three 5-position racks |
| Chemistries evaluated | Paraffin inhibitors, pour point depressants, dispersants |
| Sample types | Crude oil, client-supplied wax deposits, fluid aliquots collected during operations |
Our proprietary flow loop reproduces pipeline thermal gradients and shear regimes, so you can predict and mitigate wax deposition across a broad envelope of field conditions. Fluid moves through four stages:

As a deposit grows, the loop records it through rising pressure drop, shifting density and flow rate, and the thermal profile. Because wax insulates the pipe wall, a growing layer actually raises the fluid’s core temperature, and the thermocouple matrix captures that signature.

Off-the-shelf cold finger units rely on endpoint weighing and suffer from small air gaps that shift heat transfer from one assembly to the next. SPL redesigned the hardware tolerances to remove both problem areas:
Integrated bulk-fluid temperature probes turn a weigh-at-the-end test into a continuous one. That adds three KPIs standard units cannot provide: in-situ wax deposition onset, real-time thermal tracking, and visual inspection of deposition as it happens. It also captures sloughing and oil entrapment that endpoint weighing misses.
In a calibration series with a 50°C heat source and a 20°C cold finger, the bulk temperature settled at about 26°C in water, 33°C in kerosene, and 39°C in Sonneborn oil. Each fluid’s thermal diffusivity left a distinct fingerprint.
At 1% wax, the temperature traces separated fluids that formed deposits from those that stayed clean. An Eagle Ford crude showed a jagged profile that revealed active sloughing during the run. The Sonneborn system sat well inside the thermodynamic window for precipitation yet formed no deposit: its higher viscosity slowed crystal migration (per Stokes’ law), and its diffusivity changed local cooling enough to suppress nucleation. That is the kind of result a WAT number alone would miss, and the reason SPL measures deposition, not just precipitation.
Each program moves your samples from baseline characterization to confirmed chemical selection, so you only spend loop time on candidates that earned it.

At the end of the program you get an asset playbook built on defensible data:
A wax program is only as good as the conditions it reproduces. Send us your line inner diameter, flow rate, inlet and arrival temperatures, ambient or seabed temperature, pipe metallurgy or coating, and any current paraffin chemistry and dose.
Wax deposition testing measures when wax precipitates from crude oil and how fast it builds on a cold pipe wall. SPL combines DSC for WAT and WDT, rheology and pour point for mobility, HTGC/HTSD and SARA for composition, and cold finger and flow loop tests for deposition rate and inhibitor performance.
Wax Appearance Temperature (WAT) is the temperature where wax crystals first form as the oil cools. Wax Disappearance Temperature (WDT) is where they fully melt on reheating. SPL uses both from DSC to set the thermal boundaries for cold finger and wax loop runs.
A cold finger test is a fast, parallel screen: SPL’s re-engineered unit runs 15 stations at once to rank chemistries. A wax loop test reproduces flowing pipeline conditions, including shear and a full thermal gradient, to confirm how the best candidates perform in a moving system.
Yes. SPL screens paraffin inhibitors, pour point depressants and dispersants on the cold finger, then confirms top performers on the dynamic wax loop. An optional cost-performance analysis helps you pick the most economical dose.
Yes. The low-pressure loop covers 20°F to 150°F (-6.7°C to 65.6°C), and a high-pressure sister loop supports up to 4,000 psi (276 bar) for deepwater, reservoir-condition and live-fluid testing.
Yes. The loop’s test section accepts interchangeable pipe materials, internal coatings and liner substrates, so you can compare deposition on each before you specify a line.
Timing depends on scope. A DSC and pour point baseline finishes sooner than a full four-phase program with loop confirmation and restart testing.
SPL performs wax testing at its Flow Assurance Laboratory in Katy, Texas. Contact us for options to send samples across the United States.
Every degree of cooling you cannot quantify becomes a pigging run, a chemical overdose or a shut-in you did not plan for. Send us a sample and your operating conditions, and SPL will tell you where wax deposits, how fast, and which chemistry stops it.