We perform particulate contamination testing by FTM 3013 to measure particulate contamination in synthetic turbine engine lubricating oils. FTM 3013 is a gravimetric procedure for testing turbine lubricants. The oil sample is filtered through a very fine membrane filter; the weight of contamination left on the filter is compared to the volume of the sample to calculate the amount of particulate contamination.
Sample quantity required: 1 liter (1000 ml)
We also perform particulate contamination testing by Hach 8160, FTM 3012, ISO 4406, NAS 1638, FTM 3010, FTM 3009, ASTM D6217, ASTM D4176, ASTM D5452, ASTM D2276, ASTM D4898. These different test methods use different instruments or procedures or are used for certain sample types. Click on the test method number to learn more about each test.
Contact us today to receive a quote for your lubricants testing.